Requirement
"A functional root barrier is essential if root
penetration is to be prevented for long. From a technical viewpoint,
root barrier protection should be extended to the entire roof area,
and not restricted to just those sections of the roof that have been
planted. In the case of grasses with strong rhizome growth such as
bamboos and Chinese reeds, further, structural measures and special
care will have to be taken." FLL |
|
|
Dim.
|
FLW-800
|
|
Nominal
thickness
|
[mm]
|
0,8
|
|
Material
|
|
PVC-P
in line ith DIN 16938
|
|
Colour
|
|
Brown
|
|
Weight per
unit area
|
kg/m2
|
1,03
|
|
Tensile
strength weft
|
N×mm-2
|
24,3
|
|
Tensile
strength warp
|
N×mm-2
|
23,0
|
|
Distension
capacity weft
|
%
|
365
|
|
Distension
capacity warp
|
%
|
359
|
|
Tear
resistance weft
|
%
|
95
|
|
Tear
resistance warp
|
%
|
90
|
|
Corrugation
in the cold
|
-
|
No tears
|
|
Steam
diffusion value
|
|
8506
|
|
Root
impermeability test
|
|
Passed, TÜV
testing institute
|
|
Tests
|
|
DIN 16938
|
|
Production
|
|
ISO 9001,
ISO 9014
|
|
Other
properties
|
|
not
bitumen-resistant
not UV-resistant
|
|
Roll width
|
[m]
|
1,3
|
|
Roll lenght
|
[m]
|
35
|
|
Roll area
|
[m2]
|
45,5
|
|
Roll weight
|
[kg]
|
47
|
|
Roll
diameter
|
ca. [cm]
|
21,0
|
|
Palette
unit
|
Roll/
Palette
|
22
|
|
|
- Ensure the 2 cm overlap is clean and dry.
- Allow the blowtorch to run hot.
- Hold the welder so that the 2 cm wide nozzle heats the
whole of the overlap area and especially the outer edge of
the seal (the nozzle needs to run up to 3 cm beyond this
edge).
|
|
|
|
|
 
|
|